AQUARIUS AUTOMATION PRIVATE LTD
GST : 27AAMCA5842P1ZZ

call images

Call us

08045804566

IR Pyrometers

IR Pyrometer 1600 Deg c (Co-axial Red Laser Aiming)

Size : M 22 x 130 mm Measurement Range : 600.....1600/ 300.....1300 C Spectral Response : 1.0 / 1.6 Um Optical Resolution :150 : 1 Spot Size mm : 2.3@ 0.35 m / 10@ 1.5 m Supply Voltage : 24 V DC +- 20% Oper Temperature : + 70 `C max Output : 4..... 20 mA Temp Resolution :0.1 C Emissivity : 0.95 fixed Response : 5 ms Connection : 2 m PVC cable Protection : IP65

Hot Metal Detector

Temperature Response Rangeï ï ï ï ï ï ï : 350 - 1,500C Sensing Distanceï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï: 1 - 5 m ïDispersion Angleï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï : 7 Supply Voltageï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï: 24 V DC ïLED Indicationï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï: Green (Power),Red (Detect) ïOutput 1ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï : 3-wirePNP NO Output 2ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï: Relay NO+ NC potential free ïOperating Tempï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï: +20 - +60C(without cooling) ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï : +60 - +70C (air cooling recommended) ï ïïïïï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï ï : +70 - + 80C (water coolingrecommended

IR Pyrometer 6 digit backlit LCD display 500 deg c

Measurement Range : 0 - 500 C Display : 6digit backlit LCD display Spectral Response : 8 - 14 m OpticalResolution : 20 : 1 SpotSize (mm) : 50 @ 1.0 m Supply Voltage : 24 V DC +20% Oper. Temperature : + 70 C max Output : 4 - 20 mA / 0 - 5 V DC Temp. Resolution :.0.1 C Emissivity : 0.100 - 1000 adjustable Response : 150 ms Connection : 3 m PVC cable

IR Pyrometer 500 Deg c (Co-axial Red Laser Aiming)

Size : M22 x 130 mm Measurement Range : 600 / 1600 / 300 /1300 C Spectral Response : 10 16 m Optical Resolution : 150 1 Spot Size mm : 23 035 m 10 15 m Supply Voltage : 24 V DC 20 Oper Temperature : 70 C max Output : 4....20 mA Temp Resolution 01 C Emissivity 095 fixed Response : 5 ms Connection : 2 m PVC cable

IR Pyrometer 6 digit backlit LCD display 1600 deg c

Measurement Range : 0 - 1300 / 600 -1600 / 300 - 1300 C Display : 6digit backlit LCD display Spectral Response : 8 14 / 1.0 / 1.6 m OpticalResolution : 120 : 1 / 300 : 1 SpotSize (mm) : 100 @12 / 12 @ 3.6 / 2.3 @0.7 m Supply Voltage : 24 V DC +20% Oper. Temperature : + 70 C max Output : 4 - 20 mA / 0 - 5 V DC Temp. Resolution : 0.1 C Emissivity : 0.100 - 1.000 adjustable Response : 150 / 5 ms Connection : 3 m PVC cable Protection :IP65

IR Pyrometer AST A150

Measurement Range : 100 - 700 C Display : 6digit backlit LCD display Spectral Response : 2 - 2.6 m OpticalResolution : 50 : 1 Sighting : Laser Pilot Light Supply Voltage : 24 V DC +1 V Oper. Temperature : + 70 C (upto 200 C with cooling jacket) Output : 0/4 - 20 mA / 0 - 10 V DC Temp. Resolution : 0.1 C Emissivity : 0.1 - 1.0 adjustable Response : 2 ms adjustable upto 10 s Connection : 3 m PVC cable

Hot Metal Detector KD50 Series

Temperature Response Range :>450 C D :S ratio : 250 mm / 10 m Sensitivity Adjustment :potentiometer Supply Voltage : 230V AC LED Indication : Red(Detect) Output : Relay NO+ NC potential free Operating Temp : +20 - +60C(without cooling) : <+ 150C (with water cooling) Enclosure : Aluminum die-cast Protection : IP66

Keller ITS PKL68

  • Automation Grade:No
  • Control Mode:Manual
  • Features:Good Quality
  • Hardness:Yes
  • Operate Method:Manual
  • Power Supply:Manual
  • Usage:Industrial

Hot Metal Detector HD301N and HDA300A

Temperature ResponseRange : >350 C D :S ratio : 140 mm / 2 m Sensitivity Adjustment :potentiometer Supply Voltage : 110/ 230 V AC LED Indication : For3 levels of light intensity Output : Relay NO+ NC,Voltage12 V DC Timer : ON or OFF delay, 0.1-1sec or 1-10 sec Operating Temp : -10 -+50C Connection : HD301N : 2 mShielded Cable : HDA300A : Terminal Weight : HD301N (1.5 Kg), HDA300A(0.45 Kg)

Dual Color Pyrometer

  • Display Type:7 Segment LED
  • Temperature:65 Celsius (oC)

Handheld Pyrometer - Economy

  • Display Type:4 digit backlit LCD display
  • Power Supply:9V alkaline battery
  • Resolution:0.1 / 1.0 deg C
  • Temperature:30-1350 Celsius (oC)

Pyrometer 250

  • Temperature:0-500 Celsius (oC)
  • Voltage:24 Volt (v)

Pyrometer 500

  • Display Type:6 digit backlit LCD display
  • Temperature:0-500 Celsius (oC)

Pyrometer 1000

  • Display Type:6 digit backlit LCD
  • Temperature:Upto 65 Celsius (oC)
  • Voltage:18-30 Volt (v)

Handheld Pyrometers

  • Display Type:4 digit backlit LCD display
  • Power Supply:9V alkaline battery
  • Resolution:0.1 deg C
  • Response Time:5 Seconds
  • Temperature:30-1600 Celsius (oC)
X


Back to top